Touch screen anti ultraviolet protective film (1 pieces).Replaceable anti fouling film for protecting screen protective film (5 sheets / cover).Expansion module for the GP3000 access to the CC-Link network and communication with the CC-Link master station (support for intelligent devices)For 3.8 inch models, prevent cable loose from the USB cable fastening clip (5 / set).A veneer, for the GP4000 series back loading models of full flush (white, 1)Input voltage: DC24V
AGP3500-L1-D24-D81C
Screen size: 5.7 inches.
Display type (resolution):65536 color TFT (QVGA 320 x 240 pixels).
Touch panel type: analog resistance.
Memory: 8MB (internal memory), SRAM128KB (backup memory).
Ethernet interface: 1.
Serial port: RS-232C * 1, RS-422/485 * 1.
SD card slot (max 32GB):1.
USB interface: Type-A x (2) USB 1, Mini-B USB (2) x 1.
Replaceable battery: no (rechargeable battery).
Alarm analysis function block: No.
Panel opening size:
Wide 156 x high 123.5mm (+1/0mm).
Panel thickness: 1.6-5mm, chamfer radius is less than R3.
Coating models: there.
Easily connect a variety of USB devices
Can be easily connected to the man-machine interface serial controller, EZ series accessories, bar code reader and USB memory.
Remote data acquisition and management
Human machine interface, which is installed on the production machine,
With EX Microsoft software combined with Office Pro-Server and SQL and other standard PC software,
Can be simple and economical to establish a set of data management system, and effectively improve the quality of production and efficiency. LT4000M (module type analog), NPN output, DC24V (host).Compact Ethernet model, green / orange / red three color LED backlight.
Input voltage: DC24V.
Screen size: 3.4 inches.
Display type (resolution):STN monochrome LCD (200 x 80 pixels).
Touch panel type: analog resistance.
Memory: 2.2MB (internal memory).
Ethernet interface: 1.
Serial port: No.
SD card slot (max 32GB): No.
USB interface: Type-A x (2) USB 1, Mini-B USB (2) x 1.
Replaceable battery: no (rechargeable battery).
Alarm analysis function block: No.
Coating models: none.
The use of drag and drop operations, can be easily shared between the man-machine interface and the control program of the symbolic register data,
Make the programming process intuitive and efficient.
In addition, the common and special control function is defined as the function block, which simplifies the design of the control system.
The man-machine interface picture is directly connected with the control program, which can realize the efficient programming.
6 Display Module 2 host module, can realize the 12 kinds of "intelligent platform".
Modular design, display module and the host module can be split,
Therefore can be replaced respectively.
Display module and host module free combination, function and size of flexible.
AGP3500-L1-D24-D81C Operation manual / Instructions / Catalog download link: